Electrician Brentwood CA 90049
An electrical contractor operating in Burbank at 211 N. Victory Blvd. under the name of City Wide Electric, Lic. No. 873106 (look up the license number here), is being investigated by the California Contractors State License Board |
|
What is an AFCI?...
|
|
 Starting January 1, 2002, The National Electrical Code , Section 210-12, requires that all branch circuits supplying 125V, single phase, 15 and 20 ampere outlets installed in dwelling unit bedrooms be protected by an arc-fault Circuit interrupter. Eventually they will be in more areas but the NEC selected to require them on bedroom circuits first because a CPSC study showed many home fire deaths were related to bedroom circuits. Code Section 210-12 (a) Definition: An arc-fault circuit interrupter is a device intended to provide protection from the effects of arc faults by recognizing characteristics unique to arcing and by functioning to de-energize the circuit when an arc fault is detected. (b) Dwelling Unit Bedrooms. All branch circuits that supply 125-volt, single-phase, 15- and 20-ampere receptacle outlets installed in dwelling unit bedrooms shall be protected by an arc-fault circuit interrupter(s). This requirement shall become effective November 1, 2002. |